Arizona HVAC Load Calculations and Design Support

Plan Your HVAC Calculation and Documentation Scope.

Residential Manual J, S and D services and light commercial RTS cooling load calculations for Arizona projects. Send your plans, location and permit timeline for scope review.

The Two Problems Arizona Professionals Face Every Day

❌ Slow Response Times

A clear quote starts with the project address, available plans, requested services and target timeline. Missing details can delay scope review.

βœ“ ProCalcs reviews project details and confirms scope and scheduling.

❌ Failed Permit Submissions

Confirm which calculations, energy documents and professional design documents the local reviewer requires before ordering.

βœ“ We prepare the documents listed in your quote. The reviewing authority determines acceptance.

Start with Your Plans, Requirements and Timeline.

Typical residential turnaround is 3–5 business days after complete information and scope and scheduling confirmation. Light commercial timing is confirmed by scope.

"Why Do You Ask So Many Questions About My Project?"

Project details establish the inputs and documents to review.

Send current plans and available product specifications. Identify missing information and proposed changes before calculations are finalized so assumptions and revision scope can be discussed.

Useful information includes:
  • Project address, building use and ceiling heights.
  • Window dimensions, orientation, U-factors and SHGC.
  • Wall, roof, floor and insulation specifications.
  • Available equipment and ventilation information, local review comments and target permit timeline.

Complete information helps define the quoted work.

Confirm the applicable code and required documents with the reviewing official before ordering.

Arizona state outline map

Arizona-Specific HVAC Calculation Expertise

Arizona Codes Are Adopted Locally

Arizona is a home-rule state for building energy codes. Identify the responsible city, county or other reviewing authority and confirm its adopted edition, amendments and permit requirements for your project.

Phoenix lists the 2024 IECC in its building code effective August 1, 2025. Oro Valley lists the 2018 IECC alongside its newer building codes. One city's edition should not be applied to every Arizona address.

Project Address and Design Conditions

Use the applicable code's climate-zone information and appropriate outdoor design conditions for the actual project location. Low-desert and high-country projects need different inputs; elevation alone does not establish the code climate zone.

Send the address, plans, ceiling heights, window specifications and insulation details rather than selecting a system from a statewide temperature assumption.

Windows, Roofs and Existing Equipment

Identify window orientation, U-factors, SHGC and shading, plus roof and wall construction and any ducts outside conditioned space. For renovations, describe equipment that will remain and the proposed changes.

Available equipment performance and ventilation information help define the requested design scope. Specialty systems and field testing require separate confirmation.

Energy Documents and Quoted Scope

Confirm the accepted energy-code compliance method, forms and software settings with the reviewing authority for the building type and proposed work.

Your quote identifies included calculations and energy documents. Testing, inspections, certifications and professional engineer requirements are separate unless expressly included. Permit acceptance is determined by the reviewing authority.

Light Commercial HVAC Design in Arizona

Light Commercial Cooling Loads, Calculated the ASHRAE Way

For Arizona light commercial projects we use the Radiant Time Series (RTS) method from the ASHRAE Handbook of Fundamentals. Instead of a single design-day snapshot, RTS models how heat enters your building hour by hour, and how walls, floors and furniture delay when that heat becomes cooling load. You get a true peak hour, and equipment sized to it instead of oversized.

  1. 01Hour-by-hour cooling loads across the design day, with the true peak hour and peak month
  2. 02Thermal mass and time-delayed radiant heat gain captured, a strong fit for Arizona's block and masonry construction
  3. 03Solar gain through large glazing modeled properly for Arizona's desert sun and wide day-to-night temperature swings
  4. 04Accepted on projects where ASHRAE-based calculations are specified
  5. 05Commercial equipment, duct and air-distribution design documents as listed in your quote

Arizona light commercial projects that fit RTS

  • Small offices
  • Retail spaces
  • Restaurants
  • Mixed-use buildings
  • Buildings with large glazing
  • Heavy block and masonry construction
  • Occupancy that varies by hour
  • Specs calling for ASHRAE calculations
99occupants or fewer
15 tonsper unit, maximum

Contact us before ordering to confirm eligibility, required documents and any professional engineer requirements. Work beyond these limits is not automatically included.

GET YOUR RTS QUOTE See how the RTS method works β†’ Light commercial scope and timing confirmed before work begins.

Our Arizona HVAC Calculation Services

Manual J Load Calculations

Residential heating and cooling load calculations using project-specific inputs

Learn More β†’

Manual D Duct Design

Residential duct design coordinated with equipment and airflow information

Learn More β†’

Manual S Equipment Selection

Residential equipment selection using the load and available performance data

Learn More β†’

Commercial Load Calculations (RTS)

ASHRAE RTS cooling load calculations for eligible light commercial projects

Learn More β†’

Energy Calculations

Energy documentation as quoted, using the applicable code and accepted method

Learn More β†’

For Architects

Calculation and design documentation coordinated with the architectural scope

Learn More β†’

For Builders

Project scope and scheduling review for Arizona construction

Learn More β†’

For HVAC Contractors

Calculation and design support for the requested HVAC project scope

Learn More β†’

Find Your County Building Department

Enter your Arizona zip code to find your county's building department and specific HVAC requirements.

Need help understanding your county's specific requirements?

Contact Us for Assistance

We Serve All Arizona Counties for HVAC Calculations

ProCalcs supports HVAC calculation projects across Arizona. Send your project location and requested scope, and confirm the responsible permit reviewer and required documents before ordering.

Don't see your county? Contact us and we'll help you find the information you need.

Ready to Get Started with Your HVAC Load Calculations?

Send your plans, project location, requested services and target permit timeline. We will review the scope and confirm documents and scheduling.

Serving Arizona architects, builders, HVAC contractors, and homeowners
Project-specific scope. Clear preparation. Confirmed scheduling.

Common Questions About Arizona HVAC Load Calculations